-
GDZD-601 Automatic Multi-Function Insulation Oil Shaker
Multi-Function Shaker is used in laboratory to test heat, shake, degas various kinds of liquid under constant temperature and a fixed time. It is controlled by micro-computer to realize man-machine interaction.
-
AC High Voltage Test Sets for GIS
AC Resonant Test System for Substation Electrical Equipment, is mainly composed of variable frequency power supply, Excitation Transformers, Reactors, Capacitive dividers, which designed for AC withstand voltage test of substation electric equipment at 500kV or below.
-
PD Free Variable Frequency Test System
GDYT-350kVA/70kV PD free Resonant Test System is composed of PD free variable frequency power supply, HV measuring box, excitation transformer, isolation transformer, Resonant reactor, and capacitive voltage divider.
-
Hipot Test Set With Automatic Control
AC hi-pot testing is the effective and direct way to test insulation strength for electrical equipment, apparatus or machines. It checks dangerous flaws which assure electrical equipment continuous working.
-
Battery Impedance Tester GDBT-8612
As a key component of the power system, batteries must be tested and maintained annually, quarterly or even monthly and their test data needs to be analyzed on a regular basis.
-
GDZRS-20A Three Phase DC Winding Resistance Tester
This DC resistance quick tester (hereinafter referred to as the DC winding resistance tester) is the latest generation product for measuring the DC resistance of transformers. It is optimized for measuring the DC resistance of three-phase windings of large-capacity transformers. The DC resistance of the three-phase windings of the transformer can be tested simultaneously. For the on-load voltage regulating transformer, it is not necessary to discharge the tap changer directly, and the measurement time is one third of the traditional single-phase measurement, which can greatly shorten the working time and labor intensity. The direct resistance meter adopts a large-screen liquid crystal display, all Chinese graphical interface, clear and intuitive, and the operation is very simple. And equipped with panel printer and large-capacity non-volatile memory, you can easily store and print the measurement results. The test data is stable, fast and repeatable, and it is the best choice for measuring the DC resistance of transformers on site.
-
GDBS-305A Automatic Flash Point Closed Cup Tester
GDBS-305A automatic closed cup flash point tester is the device testing closed cup flash point for petroleum products. It widely used in the field of railway, air company, power, petroleum, and research department.
-
GDJF-2008 Partial Discharge Analyzer
GDJF-2008 Partial Discharge Detector is measuring partial discharge for the products such as transformers, mutual inductors, HV switches, zinc monoxide arresters and power cables. It also can make type tests and monitor insulation operation.
-
GDBT-8610P Battery Impedance Tester
GDBT-8610P is a new generation of battery tester with touch-screen. It is strictly designed to evaluate and maintain all stationary power systems including Uninterruptible Power System.
Via accurate testing of resistance and voltage, it gives an indication of battery capacity and technical status. The measurement data can be read on the instrument display directly. And it can also be uploaded to PC simply by using the USB drive. With the analyzing software, you could not only keep a record of the testing result but also have detailed analyzing for the status of batteries in different testing conditions.
-
GD6100 Insulation Oil Tan Delta Tester (Oil Dissipation Factor Tester)
GD6100 is high-precision instrument for testing dielectric loss angle and volume resistivity of insulating oil or other insulating liquids.
-
GLF-314 SF6 Gas Infrared Imaging Leak Detector
The SF6 infrared imaging leak detector is a non-contact gas imaging leak detection device that can detect possible gas leaks at several meters or tens of meters. It can quickly scan a large detection area and accurately find leaks in real time.
The gas detection thermal imager can detect the leakage or unorganized emission of organic volatiles, and still has good performance even for very small gas leakage.
The use of gas leakage detection is an efficient and reliable solution, which can detect the leakage of natural gas products in various links such as transportation, storage and production, so as to maximize safety and save costs.
-
GDOT-80A IEC Standard Insulation Oil Breakdown Tester 80kV
There is a large number of electrical equipment in the power system, railway system and large petrochemical plant mines and enterprises, their internal insulation is mostly oil-filled insulation. The dielectric strength of insulating oil is a mandatory routine test. In order to meet the needs of the market, our company developed and produced a series of dielectric oil dielectric strength testers according to the national standard GB/T507-2002(IEC156), the standard DL429.9-91 and the latest power industry standard DL/T846.7-2004. This instrument takes the single-chip microcomputer as the core, realizes all the automation of the test, has high measurement precision, greatly improves the work efficiency, and greatly reduces the labor intensity of the staff. At the same time, the instrument has a compact appearance and is convenient to carry.